How to charge LiPo batteries: voltage, balance, charge current
A LiPo doesn’t forgive much when you charge it: the wrong battery type, the wrong cell count or too much current, and it gets hot, swells or catches fire. Here is the voltage you charge LiPo, LiHV and Li-ion to and the one you store them at, why the balance plug belongs on the charger, how much current 1C is and what your charger’s error messages mean. Every figure comes from documents of battery and charger makers, read on Nov 13, 2026. Where they disagree, each one is listed on its own.
The short version
- Take battery type and cell count from the label. Gens Ace/Tattu: “Always set the charger to the proper cell count and/or voltage listed on Batteries’ labels.” ToolkitRC: “Choosing the wrong battery type to charge may damage the battery, the charger, and cause fire”.
- End of charge per cell: LiPo 4.2 V. LiHV mostly 4.35 V; Grepow also makes 4.4 and 4.45 V cells, so the figure on your battery counts. For Li-ion the chargers preset 4.10 V.
- Charge with the balance plug whenever the pack has one. The charger then measures every cell and evens them out. A 1S pack has nothing to balance.
- Current: 1C unless the battery maker says otherwise. 1C is the capacity as current: 1500 mAh gives 1.5 A. A big C number like 95C on the pack is the discharge rate, not the charge rate.
- Never unattended, never overnight, on a non-flammable surface, ideally in a LiPo bag. Don’t charge warm, damaged or swollen packs.
- Don’t leave packs full: if you aren’t flying, the charger’s storage mode takes them to about 3.8 V per cell.
End-of-charge and storage voltage per battery type
The end-of-charge voltage is the voltage per cell at which the charger stops. The storage voltage is where a pack should sit while you don’t use it. The tables show them as “Charge to” and “Store at”, all values per cell: battery makers first, then the charger presets. In the end, what is printed on your battery counts.
Which type is my battery? The label says so: “LiHV” or “HV” for high voltage, otherwise LiPo or Li-ion. The nominal voltage per cell is a second hint: LiPo 3.7 V, LiHV 3.8 V (ISDT, SkyRC; CNHL: “often marked 3.8V”) or 3.85 V (ToolkitRC), Li-ion 3.6 V. For a multi-cell pack, divide the nominal voltage by the cell count: 15.2 V on a 4S is 3.8 V per cell.
LiPo (nominal 3.7 V per cell)
| Source | Charge to | Store at |
|---|---|---|
| Gens Ace/Tattu (battery)manual (PDF) | 4.2 V maximum | 3.6 to 3.9 V (storage over 3 months) |
| Grepow (battery, maker of Gens Ace/Tattu)LiHV blog, storage blog | 4.2 V | 3.8 to 3.85 V |
| CNHL (battery)storage blog | 4.2 V | around 3.8 V |
| ISDT (charger, preset)Q6 Nano (PDF), 608AC (PDF) | 4.20 V | 3.80 V |
| SkyRC (charger)B6ACneo (PDF) | adjustable 4.18 to 4.22 V, 4.22 V maximum | 3.8 V |
| ToolkitRC (charger)Q6AC (PDF), M7 (PDF) | 4.20 V, adjustable ± 0.05 V | no figure in the manual |
LiHV, high-voltage LiPo (nominal 3.8 or 3.85 V per cell)
| Source | Charge to | Store at |
|---|---|---|
| BetaFPV (battery, LAVA II 1S)product page | 4.35 V | 3.85 V (spec table); 3.8 to 3.9 V for long-term storage (warnings) |
| Grepow (battery)LiHV blog | 4.35 V, depending on the cell also 4.4 or 4.45 V | 3.8 V |
| CNHL (battery)LiHV blog | 4.35 V | 3.80 to 3.85 V |
| ISDT (charger, preset)Q6 Nano (PDF), 608AC (PDF) | 4.35 V | 3.85 V |
| SkyRC (charger)B6ACneo (PDF) | 4.37 V maximum | 3.85 V |
| ToolkitRC (charger)Q6AC (PDF), M7 (PDF) | 4.35 V, adjustable ± 0.05 V | no figure in the manual |
Li-ion (nominal 3.6 V per cell)
| Source | Charge to | Store at |
|---|---|---|
| ISDT (charger, preset)Q6 Nano (PDF), 608AC (PDF) | 4.10 V | 3.70 V |
| SkyRC (charger)B6ACneo (PDF) | 4.12 V maximum | 3.7 V |
| ToolkitRC (charger)Q6AC (PDF), M7 (PDF) | 4.10 V | no figure in the manual |
| Battery and cell makers | not found on their own sites: see your pack’s label or datasheet | not found |
What the differences mean
- LiPo: every source gives 4.2 V. Grepow: “The maximum charging voltage for normal LiPo batteries is 4.2V per cell. Anything more than this is overcharging the battery”, which in the worst case means “explosions or fires”. SkyRC allows up to 4.22 V, ToolkitRC plus or minus 0.05 V, and ToolkitRC adds: “Do not modify the cut-off voltage when you are not familiar with the battery characteristics.” Storage figures range from 3.6 to 3.9 V; 3.8 V lies within every one of them.
- LiHV: 4.35 V at BetaFPV, CNHL, ISDT and ToolkitRC; SkyRC allows up to 4.37 V. Grepow also makes 4.4 and 4.45 V cells; then the figure on the pack counts. For storage the sources give 3.8 V (Grepow) to 3.85 V (BetaFPV spec table, ISDT, SkyRC); BetaFPV’s warnings say 3.8 to 3.9 V for long-term storage.
- Li-ion: the chargers preset 4.10 V, SkyRC allows at most 4.12 V. We found no figure from a battery or cell maker on its own site. Charge Li-ion as your pack’s label or datasheet says.
Wrong type selected?
Charging a LiHV in LiPo mode works according to CNHL: “It will stop at 4.20V/cell, which is safer if you’re unsure, but you won’t use the full LiHV capacity.” Not the other way round: a normal LiPo in LiHV mode would go past 4.2 V, which Grepow calls overcharging. And “many batteries that are used for drones or RC vehicles usually do not have a BMS”, so per Grepow you “should set the cut-off voltage appropriately on their chargers”.
Balance charging: what it is and why
A multi-cell pack (2S, 4S, 6S) has two plugs: the thick main connector (XT30 or XT60, say) for the charge current and the small balance plug with one wire per cell tap. Through the main lead the charger only sees the total voltage. CNHL: “A total voltage of 16.8V could still hide an unsuitable distribution such as one cell being too high and another too low.” Through the balance plug the charger measures each cell, and when “one cell may therefore reach the upper voltage limit before the others”, it “reduces current and uses its balancing circuit to control the leading cell while the lower cells continue to rise.”
SkyRC and ISDT recommend it in so many words. SkyRC: “For safety reasons, it is highly recommended to charge Lithium batteries (LiPo, Lilon, LiFe and LiHV) using Balance CHG mode unless the battery comes without a balance connector.” ISDT: “it’s strongly recommended to charge connecting with balance port”, and the charger “will alarm before operation” without it. ToolkitRC: “only connecting to the main port will not perform balance management.”
Connecting
- SkyRC: “TO AVOID SHORT CIRCUITS, ALWAYS CONNECT THE CHARGE LEADS TO THE CHARGER FIRST AND THEN TO THE BATTERY. REVERSE THE SEQUENCE WHEN DISCONNECTING.”
- Check the polarity of the charge lead and the battery before connecting (Gens Ace/Tattu).
- Balance plug into the balance port, per SkyRC “with the black wire aligned with the negative marking”. CNHL: don’t force it, don’t insert it offset by one pin, don’t reverse it and don’t pull it by its wires.
- Count check: “A conventional balance connector normally has one more wire than the series cell count”, so a 4S has 5 (CNHL). That doesn’t replace reading the label.
1S packs (whoops)
CNHL: “A 1S pack has only one cell, so there are no cells to balance against each other. It still requires the correct chemistry mode and voltage limit.” Some 1S whoop packs are LiHV, BetaFPV’s LAVA II with 4.35 V for one. Which batteries and chargers suit a whoop is in Buying your first FPV drone.
Step by step: setting up the charger
- Check the battery: packaging, wires and connectors free of damage (Gens Ace/Tattu), not deformed or swollen (BetaFPV), not warm. Gens Ace/Tattu also say: “Always check the voltage of Batteries before each charge session”.
- Place: on a “heat-resisting, non-flammable and insulating surface” (ISDT), away from flammable materials, not “on car seats, carpets, or similar surfaces” (SkyRC). Take the pack out of the quad: “Never charge Batteries inside of the model.” (Gens Ace/Tattu)
- Connect as above: charge lead, main plug, balance plug.
- Battery type: LiPo, LiHV or Li-ion, as on the label.
- Mode: balance charge. SkyRC calls it “Balance CHG”; on ISDT and ToolkitRC chargers “Charge” balances as soon as the balance plug is in.
- Cell count as on the label. If it is set to “Auto”, check the detected number: ToolkitRC warns that over-discharge or overcharge “may cause battery cell identification errors”, and with the balance plug in the cells “can be more accurately identified”. A wrong cell count can overcharge the pack.
- Current, see the next section. Gens Ace/Tattu: “DO NOT alter the charge rate once charging has begun.”
- Start and stay. When it is full, end the task and “remove the battery when the charger shows the standby screen” (ISDT). “Do not connect the charger and the battery for a long time when the battery is fully charged.” (Gens Ace/Tattu)
Charge current: what 1C means
C relates the current to the capacity. 1C means as many amps as the pack has amp-hours. CNHL: “1C = capacity(mAh) ÷ 1000.” For another rate, multiply by C; ISDT: “for a 1000 mAh battery with a charging capacity of 5C, the maximum charging current would be 1000*5=5000mA”.
| Capacity | 0.5C | 1C | 2C |
|---|---|---|---|
| 500 mAh | 0.25 A | 0.5 A | 1.0 A |
| 1000 mAh | 0.5 A | 1.0 A | 2.0 A |
| 1500 mAh | 0.75 A | 1.5 A | 3.0 A |
| 2200 mAh | 1.1 A | 2.2 A | 4.4 A |
ISDT on charge time: “charging time ≥60 minutes/ charging C value (e.g. it needs around 60-70 minutes to complete charging with 1C)”. It slows down near the end: CNHL explains that the charger “changes from the constant-current stage to the constant-voltage and balancing stages”.
What the makers say about charge current
- Gens Ace/Tattu: “The charger should never be set to charge Batteries at a rate greater than 1C (One (1) times the capacity of Batteries in amp hours) unless another C rate is specified in the manufacturer’s product documentation or the rate is preset as part of a specific battery and charger combination.”
- SkyRC: “Allowable fast charge current” ≤1C for LiPo, LiHV and Li-ion.
- ISDT: “Multiplying the charging C value and battery capacity equals to the maximum charging current supported by the battery.” And: “For a lithium battery, if it is impossible to confirm the supported charging C value, please set the charging current below 1C”.
- Grepow for LiHV: “0.5–1C”. CNHL for LiHV: “Start at 1C or below”.
- ToolkitRC: “Please set the charging rate of 1-2C according to the battery capacity. For example, if the battery capacity is 2000mAh, please set the charging current to 2.0-4.0A. Check the guidelines of your battery’s manufacturer for correct charging instructions.”
Here the sources disagree: ToolkitRC says up to 2C across the board, Gens Ace/Tattu and SkyRC set 1C as the limit unless the battery maker states otherwise. They all agree that what is specified for your pack comes first. If the label or datasheet gives no charge rate, stay at 1C or below, as Gens Ace/Tattu, SkyRC and ISDT write.
The big C number on the pack
Don’t mistake the big C number on the pack for the charge rate. On BetaFPV’s LAVA II, for example, the 95C is explicitly the “discharge rate”. For charging, the charge rate counts (ISDT: “charging C value”) if the maker gives one; otherwise 1C applies as above.
Can the charger deliver it?
Power is voltage times current. CNHL: “A 6S 5000mAh battery at 1C requires approximately 126W near full voltage”, that is 25.2 V times 5 A; a 6S 1300 mAh at 1C needs about 33 W the same way. For 2C, CNHL lists that the battery must permit it and charger, power supply, connectors and charge lead must handle the current and wattage.
Charging safely: what makers and authorities require
- Don’t leave it alone. SkyRC: “Never leave charging batteries unattended during use. Never charge batteries overnight.” ISDT: “NEVER USE CHARGER UNSUPERVISED”. ToolkitRC: “Never leave charging batteries unattended.” BetaFPV: “never leave the battery unattended during the charging process”. Gens Ace/Tattu: “Don’t charge without monitoring.” The German Environment Agency (UBA) adds: stay nearby while charging and don’t charge while you sleep.
- Surface and surroundings. ISDT: “Place the charger on a heat-resisting, non-flammable and insulating surface.” Gens Ace/Tattu: “Always charge Batteries in an open area away from flammable materials, liquids and surfaces.” The UBA recommends a room with a smoke detector and nothing flammable nearby, and advises against charging outdoors, in damp rooms or in very hot places.
- LiPo bag. Gens Ace/Tattu: “Using lipo sack is suggested when charging to ensure the charging safety.” For storage: “store Batteries in a non-conductive and fireproof container.”
- Not in the quad. Gens Ace/Tattu: “Never charge Batteries inside of the model.”
- Not warm. Gens Ace/Tattu: “Never charge Batteries that are hot to the touch (above 100° F). DO NOT handle Batteries until they are cool.” So let it cool after a flight; CNHL: “Heat plus high voltage is what accelerates aging.” SkyRC: “Never charge batteries in extremely hot or cold places or place in direct sunlight.”
- Damaged or swollen: don’t charge. SkyRC: “Never attempt to charge dead, damaged, or wet battery packs.” BetaFPV: “Do not use batteries that are deformed or swollen.” The UBA says the same for defective, damaged, deformed and swollen batteries.
- Over-discharged: don’t charge. Gens Ace/Tattu: “If starting voltage is below recommended levels then Batteries have been over discharged or have experienced a failure and should NOT be charged.” Such packs “may be damaged, resulting in loss of performance and potential fire when Batteries are charged.” The manual gives no figure for that limit. As the limit in use, Gens Ace/Tattu and BetaFPV give “3V per cell under load”.
- If it gets hot or swells while charging: Gens Ace/Tattu: “discontinue charging or discharging immediately. Quickly and safely disconnect the battery from the charger or model. Then place the battery and/or charger in a safe, open area, away from flammable materials inside a fireproof container (such as a LiPo safety bag). After one hour, if the battery condition has stabilized, remove the battery from service. Do not continue to handle, attempt to use, or ship the battery.” The UBA advises taking damaged batteries to a collection point with taped poles in a closable container.
Storage mode: taking packs to storage voltage
If you won’t fly in the next few days, don’t leave packs full. BetaFPV: “Do not store fully charged batteries for more than 3 days.” Grepow: “If you leave your battery at maximum voltage, you run the risk of decreasing the battery’s lifespan and causing your battery to swell.” That is what the charger’s storage mode is for; SkyRC: “This mode is to store the battery via charging or discharging its votlage to a specific storage value.” The target values are in the tables above.
Don’t confuse it with “Discharge”. CNHL: “If you mistakenly use "Discharge" mode, the charger will continue discharging the battery until it’s completely drained, which can damage the battery.” Discharging also takes longer than charging, because chargers discharge with far less power; ISDT’s Q6 Nano charges with up to 200 W and discharges with at most 10 W. How to store packs for longer, where and at what temperature, and how to dispose of them is in How to store and dispose of LiPos.
Charger errors: message, cause, fix
The messages differ from charger to charger. The English messages below are from the SkyRC B6ACneo manual, as the charger displays them. Causes and fixes come from the SkyRC, ISDT and ToolkitRC manuals and the battery makers’ instructions. For other chargers, look for “Errors” or “Warnings” in their manual.
Connection and settings
“Balance Connection Error”
- Cause
- SkyRC: “The balance connection is incorrect.” The plug goes in “with the black wire aligned with the negative marking”. CNHL adds: offset by one pin, reversed, not fully inserted or a damaged lead.
- Fix
- Unplug, look at the plug and the wires, insert it the right way round and all the way, without force. If the charger still can’t read all cells, CNHL says: “stop and inspect the plug, wires, balance board and charger port.” Don’t charge with a visibly damaged balance lead.
The charger beeps or warns before it starts
- Cause
- On ISDT chargers: you are charging a LiPo without the balance plug. “Warning beeper will yell before start charging lipo if in non-balance mode” (Q6 Nano, 608AC). ToolkitRC: “only connecting to the main port will not perform balance management” (Q6AC).
- Fix
- Plug in the balance lead, then start. A 1S pack has nothing to balance.
“Reversed Polarity”
- Cause
- Plus and minus are swapped: “The battery connection is reversed!” (SkyRC).
- Fix
- Disconnect at once. Check the polarity of the charge lead, adapter and battery before connecting again (Gens Ace/Tattu).
“Connection Break!” or a battery connection error
- Cause
- “The battery connection is broken!” (SkyRC). ISDT also names contacts that are “oxidized or burned”.
- Fix
- ISDT: “pull out and plug in the battery again to ensure all connections are reliably contacted; if the error reminder continues, please check whether the metal parts on the battery interface are oxidized or burned”.
“Battery Type Error”
- Cause
- “The battery type is wrong!” (SkyRC).
- Fix
- Set the type from the label: LiPo, LiHV or Li-ion (how to tell). ToolkitRC: “Choosing the wrong battery type to charge may damage the battery, the charger, and cause fire”, and don’t charge “the battery that is not marked with the battery type”.
“Cell Error”, a cell count warning, or “Auto” detects a different cell count than the label
- Cause
- SkyRC explains “Cell Error” only as “The cells do not match.” (manual). ISDT has an “Incorrect cell count setting alarm” (Q6 Nano). ToolkitRC: “Over discharge or overcharge of the connected battery may cause battery cell identification errors.” CNHL lists: wrong manual setting, very low cell voltage, damaged or loose balance lead, wrong position on the balance board, battery damage.
- Fix
- CNHL: “do not repeatedly confirm through the warning.” Set the cell count by hand as on the label, plug in the balance lead (ToolkitRC then detects the cells more accurately) and look at every cell voltage. A wrong cell count “may damage the battery” by overcharging (ToolkitRC). If one cell is very low, go on with over-discharged.
Cells and battery
“Cell Volt Diff.” or one cell is far off the others
- Cause
- “The voltage difference between each cell is high.” (SkyRC). CNHL: “Limited imbalance can be normal. A cell that repeatedly drifts farther from the others may indicate battery aging, a weak cell or a balance-connection problem.”
- Fix
- Check the balance connection first. The makers differ in how strict they are: Gens Ace/Tattu: “Stop using it if user found the cells are not balanced”; CNHL suggests tracking whether the difference repeats or grows and inspecting battery and balance connection for a clear outlier.
The pack or one cell shows very low voltage before charging
- Cause
- Over-discharged or failed. As the limit in use, Gens Ace/Tattu and BetaFPV give “3V per cell under load”. Gens Ace/Tattu give no figure below which you must not charge.
- Fix
- Don’t charge it. Gens Ace/Tattu: “If starting voltage is below recommended levels then Batteries have been over discharged or have experienced a failure and should NOT be charged.” Over-discharged packs may cause a “potential fire when Batteries are charged”. Retire it.
The battery gets hot or swells while charging
- Cause
- The cell is damaged or overloaded. CNHL says to stop at once if “The battery swells”, “The pack becomes unusually hot”, a connector gets hot, or there is smoke, leakage or an abnormal smell.
- Fix
- Gens Ace/Tattu: “discontinue charging or discharging immediately. Quickly and safely disconnect the battery”, place it “in a safe, open area, away from flammable materials inside a fireproof container (such as a LiPo safety bag). After one hour, if the battery condition has stabilized, remove the battery from service.” Never charge a swollen pack again (BetaFPV: “Do not use batteries that are deformed or swollen.”).
Charger and power supply
“Int. Temp Too High”
“DC In Too Low” or a low input voltage warning
- Cause
- “DC input voltage is lower than preset or min.input voltage!” (SkyRC). On ISDT chargers every task stops; this “will protect the battery from being discharged when using battery pack as power supply” (Q6 Nano).
- Fix
- Check and charge the power supply or input battery. The input range is in the manual; for the Q6 Nano it is DC 10 to 30 V.
Charged: what next?
Battery in, quad won’t arm? Betaflight shows the reason as an arming flag; what each one means is in Quad won’t arm: all arming flags. And if you are just starting out: which batteries and which charger suit the beginner whoops is in Buying your first FPV drone.
Sources
As of Nov 13, 2026; every document was read that day. Nothing here was tested on a device; figures and messages come from the makers’ documents and the German Environment Agency. Maker names appear as sources, not as recommendations.
- Battery makers: Gens Ace/Tattu, LiPo operating instructions (PDF), Grepow, What is a LiHv battery?, Grepow, storing LiPo batteries, BetaFPV, LAVA II 1S (spec table and warnings), CNHL, how to charge and store LiHV batteries, CNHL, storage charging LiPo batteries, CNHL, how to balance charge a LiPo, CNHL, LiPo charger modes explained.
- Chargers: ISDT, Q6 Nano manual (PDF), ISDT, 608AC manual (PDF), ISDT, D2 manual (PDF), SkyRC, B6ACneo manual V1.3 (PDF), ToolkitRC, Q6AC manual V1.2 (PDF), ToolkitRC, M7 manual V1.0 (PDF).
- Authority: German Environment Agency (UBA), handling lithium batteries (German).
Last updated: Nov 14, 2026